Page 10 of 27 The Analyst RS422/RS232 Tester
F. Monitor Serial Communication Between Equipment
Use MONITOR Mode to monitor serial communication between two pieces of equipment.
1) From the MAIN Screen, press the [MENU] key.
2) Press the [IN] and [OUT] keys to toggle between RS422 and RS232. Select
either RS422 or RS232 to match the equipment being monitored.
3) Press the [Exit] key to exit the MENU Screen.
4) Press the [MON] key to select MONITOR Mode.
5) Connect The Analyst RS422/RS232 Tester between the two pieces of equipment.